Microfreak/UG/06 Dig Osc/03 Types/18 Sample
06.03.18 Sample
- Sample Oscillator Model
- Description: The Sample oscillator works like WaveUser, with user samples loaded through MIDI Control Center. The MicroFreak stores 128 samples, with up to 210 seconds of audio in total.
- To browse samples, hold Shift and turn the Type knob. This opens the sample select menu for the unit's 128 slots; repeat the gesture to leave the menu.
Note/Info When adjusting Sample parameters,
| Smpat the top of the screen means the sample select menu is still open.- Sample display showing
| Smpand the Start parameter - Start: The Wave knob sets the sample's starting point, from 0 at the beginning to 100 at the end.
- Length: The Timbre knob sets sample length from -100 to 100. Negative values play the sample backward.
Note/Info With Start at 100 and Length at -100, the sample plays backward from its end to its start.
- Loop: After setting Start and End with Length, Loop crossfades between those positions. At 100, only a very short part at the end of the sample loops.